The Paxton Net2 I/O Board 12V 2A PSU with Plastic Cabinet is a compact interface board that expands the functionality of Paxton Net2 access control systems. Designed to work alongside Net2 door controllers, it allows administrators to extend signals to devices such as alarms, sensors, and other equipment, helping automate responses to events or schedule-based tasks.
The board features four inputs and four relay outputs that can be configured via Paxton Net2 Pro software using triggers and actions. Inputs respond to system events, and outputs can control connected devices automatically, ensuring alarms, panic-buttons, sensors or other equipment operate as programmed. Clear labelling makes it easy to manage and monitor each input and output.
Housed in a plastic cabinet with a built-in 12V 2A power supply, the board connects directly to the network for flexible deployment. It can be positioned wherever inputs and outputs are required with straightforward installation. Simply wire the devices, mount the cabinet, and configure via Paxton Net2 Pro software. No additional power modules or complex setup steps are required.
Back To TopElectrical |
|
| Operating Voltage: | 10V - 24V DC |
| Current consumption: | 400mA |
| Inputs: | 4 |
| Outputs: | 4 |
| Relay contact current rating: | 15A |
| Relay contact isolation: | 4kV AC |
| Relay contact voltage: | 240V AC |
| Relay contact frequency: | 50Hz |
Communication |
|
| TCP/IP: | Yes (Maximum 200 including other ethernet devices - Net2 Plus, I/O Boards) |
| Wireless: | No |
| RS485: | No |
| Ethernet network speed: | 100Mbit/s auto MDIX |
| Ethernet bandwidth requirement: | 24V DC |
| DHCP support (fixed IP recommended): | Yes |
Environment |
|
| Operating temperature: | 0°C - +45°C
+32°F - +113°F |
| Moisture resistance: | No - if used externally, it must be protected in a weatherproof housing |
| Vandal resistance: | Low |